Volume 4, Issue 1 And 2 (1-2016)                   J Surg Trauma 2016, 4(1 And 2): 7-10 | Back to browse issues page

XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Abdi R, Aboobakri M. The use of combined 3.5 LCP unicortical plate and nail fixation in proximal tibia fractures and prevention of valgus and anterior angulation . J Surg Trauma 2016; 4 (1 and 2) :7-10
URL: http://jsurgery.bums.ac.ir/article-1-80-en.html
Assistant Professor, Department of Pediatric Orthopedics, Faculty of Medicine, Birjand University of Medical Sciences, Birjand, Iran
Abstract:   (4309 Views)

Introduction: Intramedullary nailing (IMN) of high tibia fracture has some mechanical and biological advantages over the other form of fixation. However, valgus, apex anterior malalignment and anterior displacement of proximal fragment commonly occur after isolated IMN fixation of proximal high tibia fracture. The purpose of this study is to determine the effectiveness of using 3.5-mm locking compression plate (LCP) with unicortical screws combined with IMN fixation to maintain the difficult reduction and prevent any displacement after classic nail insertion.

Methods: This cross-sectional study was performed between 2010 and 2012, thirty-three open or closed tibia fractures involving the high proximal tibia metaphysis were operated using combined 3.5 mm LCP unicortical plate with the classic reamed intramedullary nailing technique. The clinical and radiological results of the study were collected on the basis of the time to ::::::::union::::::::, non::::::::union::::::::, mal::::::::union::::::::, degree of angulations at the fracture site, and infection. Follow-up ranged from 24 to 36 months (mean 28 months).

Results: The ::::::::union:::::::: rate was 100% on radiographs at 3.38 months postoperatively. No complications such as mal::::::::union::::::::, delayed ::::::::union::::::::, implant failure, prominent valgus, anterior angulation malalignment, or postoperative deep infection occurred.

Conclusions: Although prominent malalignment occurs after IM nailing of proximal one-third tibia fractures, we can avoid it by using the medially inserted 3.5 LCP unicortical plate. The results are good even in open fracture type one or two.

Full-Text [PDF 930 kb]   (2396 Downloads)    
Type of Study: Research |
Received: 2017/01/1 | Accepted: 2017/04/4 | Published: 2017/04/21 | ePublished: 2017/04/21

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 CC BY-NC 4.0 | Journal of Surgery and Trauma

Designed & Developed by : Yektaweb