دوره ۱۲، شماره ۴ - ( ۱۰-۱۴۰۳ )                   جلد ۱۲ شماره ۴ صفحات ۱۵۹-۱۵۶ | برگشت به فهرست نسخه ها

XML English Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Nikouyeh M, Raee A, Saeedmanesh E, Jafari M A, Esmaeli A, Zeinali F. Application of Ultrasound in the Identification of Foreign Bodies in Scalp Wound: A Cross-sectional Study. J Surg Trauma 2024; 12 (4) :156-159
URL: http://jsurgery.bums.ac.ir/article-1-425-fa.html
Application of Ultrasound in the Identification of Foreign Bodies in Scalp Wound: A Cross-sectional Study. نشریه جراحی و تروما. ۱۴۰۳; ۱۲ (۴) :۱۵۶-۱۵۹

URL: http://jsurgery.bums.ac.ir/article-۱-۴۲۵-fa.html


چکیده:   (۱۸۴ مشاهده)
Introduction: Retained foreign bodies in wounds are among the most challenging problems in the emergency department (ED). They lead to wound infection and abscess, delayed healing, and wound scars.  Therefore, the present study aimed to determine the diagnostic value of ultrasound as an accessible and non-invasive modality in determining foreign bodies in scalp wounds.
Methods: This cross-sectional analytical study was performed on 58 ED patients with scalp wounds who needed brain computed tomography (CT) scans and met the inclusion criteria. Firstly, wound exploration and irrigation of visible foreign bodies were performed. Thereafter, an ultrasound was carried out by an emergency medicine resident to detect the hidden foreign bodies (if exist) in the wound. Finally, a CT scan was administered (as the gold standard) to detect any remained foreign bodies. The foreign bodies were removed and the wound was sutured in the end. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, disease prevalence, positive predictive value, negative predictive value, and accuracy were assessed.
Results: In total, the sensitivity, specificity, and accuracy of ultrasound were estimated as 91.43%, 100%, and 91.55%, respectively. Moreover, the positive predictive value and negative predictive value of ultrasound were reported as 100%and 14.29%, respectively.
Conclusion:  As evidenced by the results of this study, ultrasound is a highly sensitive diagnostic method to detect foreign bodies in scalp wounds. In some cases, such as frontal lobe wounds, this modality may not detect all foreign bodies.
متن کامل [PDF 434 kb]   (۷۴ دریافت)    
نوع مطالعه: مقاله کوتاه | موضوع مقاله: تروما
دریافت: 1403/1/26 | پذیرش: 1403/9/15 | انتشار الکترونیک پیش از انتشار نهایی: 1403/9/30 | انتشار: 1403/10/10

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
CAPTCHA

بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.

کلیه حقوق این وب سایت متعلق به نشریه جراحی و تروما می باشد.

طراحی و برنامه نویسی : یکتاوب افزار شرق

© 2025 CC BY-NC 4.0 | Journal of Surgery and Trauma

Designed & Developed by : Yektaweb